Ammonia Cheqker Hanna Instruments |
|
Ammonia Low Range Checker® HC - HI700 |
|
Specifications |
|
Range |
0.00 to 3.00 ppm NH3-N |
Resolution |
0.01 |
Accuracy @ 25°C |
±0.05 ppm ±5 % of reading |
Light source |
LED @ 470 nm |
Light Detector |
Silicon photocell |
Method |
Adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample. |
Environment |
0 to 50°C; RH max 95% non-condensing |
Battery Type |
( 1 ) 1.5V AAA |
Auto-off |
After ten minutes of non-use |
Dimensions |
81.5 mm x 61 mm x 37.5 mm |
Weight |
64 g |
Ordering Information |
HI-700 Checker® is supplied with ( 2 ) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI-700A-0 reagent A and 1 bottle of HI-700B-0 reagents B), battery, instructions. |
Ammonia Medium Range Checker® HC - HI715 |
|
Specifications |
|
Range |
0.00 to 9.99 ppm NH₃-N |
Resolution |
0.01 ppm |
Accuracy @ 25°C/77°F |
±0.05 ppm ±5% of reading |
Light Source |
LED @ 470 nm |
Light Detector |
Silicon photocell |
Method |
Adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample. |
Environment |
0 to 50°C ( 32 to 122°F ); RH max 95% non-condensing |
Battery Type |
( 1 ) 1.5V AAA |
Auto-off |
After ten minutes of non-use |
Dimensions |
81.5 mm x 61 mm x 37.5 mm ( 3.2" x 2.4" x 1.5” ) |
Weight |
64 g ( 2.25 oz .) |
Ordering Information |
HI715 Checker® is supplied with ( 2 ) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI715A-0 and 1 bottle of HI715B-0), battery, instructions and quick start guide. |
Ammonia High Range Checker® HC - HI733 |
|
Specifications |
|
Range |
0.0 to 99.9 ppm as NH₄⁺ |
Resolution |
0.1 ppm |
Accuracy @ 25°C/77°F |
±1.0 ppm ±5 % of reading |
Light Source |
LED @ 470 nm |
Light Detector |
Silicon photocell |
Method |
Adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample. |
Environment |
0 to 50°C ( 32 to 122°F ); RH max 95% non-condensing |
Battery Type |
( 1 ) 1.5V AAA |
Auto-off |
After ten minutes of non-use |
Dimensions |
81.5 mm x 61 mm x 37.5 mm ( 3.2" x 2.4" x 1.5” ) |
Weight |
64 g ( 2.25 oz. ) |
Ordering Information |
HI733 Checker® is supplied with ( 2 ) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI733A-0 and 1 bottle of HI733B-0 ), battery, instructions and quick start guide |