Benchtop Turbidity Meter Hanna Instrument |
|
|
Benchtop Turbidity and Chlorine Meter - HI83414 |
|
|
Turbidity Spec |
|
|
Non-Ratio Mode Range |
0.00 to 9.99; 10.0 to 40.0 NTU; 0.0 to 99.9; 100 to 268 Nephelos; 0.00 to 9.80 EBC |
|
Non-Ratio Mode Resolution |
0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC |
|
Ratio Mode Range |
0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU; 0.0 to 99.9; 100 to 26800 Nephelos; 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC |
|
Ratio Mode Resolution |
0.01; 0.1; 1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC |
|
Range Selection |
automatic |
|
Accuracy |
±2 % of reading plus 0.02 NTU ( 0.15 Nephelos; 0.01 EBC ); ±5 % of reading above 1000 NTU ( 6700 Nephelos; 245 EBC ) |
|
Repeatability |
±1 % of reading or 0.02 NTU ( 0.15 Nephelos; 0.01 EBC ) whichever is greater |
|
Stray Light |
< 0.02 NTU ( 0.15 Nephelos; 0.01 EBC ) |
|
Light Detector |
silicon photocell |
|
Method |
nephelometric method ( 90° ) or ratio nephelometric method ( 90° & 180° ), adaptation of the USEPA Method 180.1 and Standard Method 2130 B |
|
Measuring Mode |
normal, average, continuous |
|
Turbidity Standards |
< 0.1, 15, 100, 750 and 2000 NTU |
|
Calibration |
two, three, four, or five-point calibration |
|
Free and Total Chlorine Spec |
|
|
Free and Total Chlorine Range |
0.00 to 5.00 mg/L (ppm) |
|
Free and Total Chlorine Resolution |
0.01 mg/L ( ppm ) from 0.00 to 3.50 mg/L ( ppm ); 0.10 above 3.50 mg/L ( ppm ) |
|
Free and Total Chlorine Accuracy |
±0.02 mg/L @ 1.00 mg/L |
|
Light Detector |
silicon photocell with 525 nm narrow band interference filter |
|
Method |
adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. |
|
Standards |
1.00 mg/L ( ppm ) free chlorine; 1.00 mg/L ( ppm ) total chlorine |
|
Calibration |
one-point calibration |
|
General Spec |
|
|
Light Source |
tungsten filament lamp / greater than 100,000 readings |
|
Display |
40 x 70 mm graphic LCD ( 64 x 128 pixels ) with backlight |
|
Log Memory |
200 records |
|
Connectivity |
USB |
|
Environment |
0 to 50 °C ( 32 to 122 °F ), RH max 95 % non-condensing |
|
Power Supply |
115/130 VAC; 50/60 Hz |
|
Dimensions |
230 x 200 x 145 mm ( 9.0 x 7.9 x 5.7” ) |
|
Weight |
2.5 kg ( 88 oz ) |
|
Benchtop Turbidity Meter - HI88703 |
|
|
Turbidity Spec |
|
|
Non-Ratio Mode Range |
0.00 to 9.99; 10.0 to 40.0 NTU; 0.0 to 99.9; 100 to 268 Nephelos; 0.00 to 9.80 EBC |
|
Non-Ratio Mode Resolution |
0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC |
|
Ratio Mode Range |
0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU; 0.0 to 99.9; 100 to 26800 Nephelos; 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC |
|
Ratio Mode Resolution |
0.01; 0.1; 1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC |
|
Range Selection |
automatic |
|
Accuracy |
±2% of reading plus 0.02 NTU ( 0.15 Nephelos; 0.01 EBC ); ±5% of reading above 1000 NTU ( 6700 Nephelos; 245 EBC ) |
|
Repeatability |
±1% of reading or 0.02 NTU ( 0.15 Nephelos; 0.01 EBC ) whichever is greater |
|
Stray Light |
< 0.02 NTU ( 0.15 Nephelos; 0.01 EBC ) |
|
Light Detector |
silicon photocell |
|
Method |
nephelometric method ( 90° ) or ratio nephelometric method ( 90° & 180° ), adaptation of the USEPA Method 180.1 and Standard Method 2130 B |
|
Measuring Mode |
normal, average, continuous |
|
Turbidity Standards |
< 0.1, 15, 100, 750 and 2000 NTU |
|
Calibration |
two, three, four, or five-point calibration |
|
General Spec |
|
|
Light Source |
tungsten filament lamp / greater than 100,000 readings |
|
Display |
40 x 70 mm graphic LCD ( 64 x 128 pixels ) with backlight |
|
Log Memory |
200 records |
|
Connectivity |
USB |
|
Environment |
0 to 50°C ( 32 to 122°F ), RH max 95 % non-condensing |
|
Power Supply |
115/130 VAC; 50/60 Hz |
|
Dimensions |
230 x 200 x 145 mm (9.0 x 7.9 x 5.7”) |
|
Weight |
2.5 kg ( 88 oz ) |