Ammonia Meter HI-96733 Hanna Instrument |
|
Ammonia High Range Portable Photometer - HI96733 |
|
Absorbance Specifications |
|
Light Source |
Tungsten lamp |
Light Detector |
Silicon photocell with narrow band interference filter @ 420 nm |
Additional Specifications |
|
Range |
0.0 to 50.0 mg/L ( ppm ) as NH₄+ |
Resolution |
0.01 mg/L ( ppm ) |
Accuracy @ 25°C ( 77°F ) |
±0.5 mg/L ±5 % of reading |
Method |
Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler method |
Auto-off |
After ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment |
0 to 50 °C ( 32 to 122 °F ); RH max 95% non-condensing |
Weight |
360 g ( 12.7 oz. ) |
Battery Type |
9 V battery |
Dimensions |
193 x 104 x 69 mm ( 7.6 x 4.1 x 2.7” ) |
Ordering Information |
HI96733 is supplied with sample cuvettes ( 2 ) with caps, 9 V battery, instrument quality certificate and instruction manual |
Ammonia Low Range Portable Photometer - HI96700 |
|
Absorbance Specifications |
|
Light Source |
Tungsten lamp |
Light Detector |
Silicon photocell with narrow band interference filter @ 420 nm |
Additional Specifications |
|
Range |
0.00 to 3.00 mg/L ( ppm ) (as ammonia-nitrogen) |
Resolution |
0.01 mg/L |
Accuracy @ 25°C ( 77°F ) |
±0.04 mg/L ±4 % of reading |
Method |
Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler method |
Auto-off |
After ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment |
0 to 50 °C (32 to 122 °F ); RH max 95 % non-condensing |
Weight |
360 g ( 12.7 oz.) |
Battery Type |
9 V battery |
Dimensions |
193 x 104 x 69 mm ( 7.6 x 4.1 x 2.7” ) |
Ordering Information |
HI96700 is supplied with sample cuvettes ( 2 ) with caps, 9V battery, instrument quality certificate and instruction manual. |
Ammonia Medium Range Portable Photometer - HI96715 |
|
Absorbance Specifications |
|
Light Source |
Light emitting diode |
Light Detector |
Silicon photocell with narrow band interference filter @ 466 nm |
Additional Specifications |
|
Range |
0.00 to 9.99 mg/L ( ppm ) ( as NH₃-N ) |
Resolution |
0.01 mg/L |
Accuracy @ 25 °C ( 77 °F ) |
±0.05 mg/L ±5 % of reading |
Method |
Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler method |
Auto-off |
After ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment |
0 to 50 °C ( 32 to 122 °F ); RH max 95 % non-condensing |
Weight |
360 g ( 12.7oz.) |
Battery Type |
9V battery |
Dimensions |
193 x 104 x 69 mm ( 7.6 x 4.1 x 2.7” ) |
Ordering Information |
HI96715 is supplied with sample cuvettes ( 2 ) with caps, 9 V battery, instrument quality certificate and instruction manual |