LTC3000W Series Laboratory Turbidity, Chlorine and Color Meter Lamotte |
|
1. LTC3000we Laboratory Turbidity & Chlorine Meter; |
|
Turbidity ( EPA 180.1 ), Chlorine ( EPA 330.5 ), Color ( based on Standard Methods 2120C ) :1972-EPA |
|
2. LTC3000wi Laboratory Turbidity & Chlorine Meter; |
|
Turbidity ( ISO 2027 ), Chlorine ( Standard Methods 4500-Cl-G ), Color ( based on Standard Methods 2120C ):1972-ISO |
|
Turbidity Specifications |
|
Unit of Measure |
NTU, FNU, AU, FAU, ASBC, EBC |
Range* |
0-4000, 0-10,500 ASBC, 0-150 EBC |
Resolution* |
0.01 NTU/FNU 0.00-10.99 |
0.1 NTU/FNU 11.00-109.9 |
|
1 NTU/FNU 110-4000 |
|
Accuracy* |
From 0-2.5 NTU the accuracy is ±0.05 NTU. |
From 2.5-100 NTU the accuracy is ±2 %. |
|
Above 100 NTU the accuracy is ±3 % |
|
Range Selection |
Automatic |
Detection Limit |
0.05 NTU/FNU |
Reproducibility* |
0.02 NTU/FNU, or 1 % |
Light Source |
Tungsten ( EPA ), complies with EPA 180.1860mm LED ( ISO ), compies with ISO 7027 |
Chlorine Specifications |
|
Range |
0-10 ppm, Free and Total Chlorine |
Resolution |
0.00-5.00 ppm Range : 0.01 ppm |
5.0-10.0 ppm Range : 0.1 ppm |
|
Accuracy Tablet |
0-1.0 ppm Range : ±0.03 ppm |
1.0-3.0 ppm Range : ±0.06 ppm |
|
3.0-6.0 ppm Range : ±0.3 ppm |
|
6.0-10.0 ppm Range : ±2.5 ppm |
|
Liquid |
0-0.5 ppm Range : ±0.03 ppm |
0.6-3.0 ppm Range : ±0.06 ppm |
|
3.0-6.0 ppm Range : ±0.4 ppm |
|
6.0-10.0 ppm Range : ±1.5 ppm |
|
Detection Limit |
0.03 ppm |
Response Time |
<2 seconds="" --2--=""> |
Light Source |
525 nm LED, complies with EPA 330.5 |
Color Specifications |
|
Range |
0-1000 cu |
Detection Limit |
20 cu |
Accuracy |
±15 cu |
Light Source |
428 nm LED |
Meter Features |
|
Signal Averaging |
Disabled, 2, 5, 10 |
Power |
USB computer cable or wall adapter or Lithium ion rechargeable battery, 3.7 V, 2.5" x .75", 1.7 oz. |
Data Logging |
500 points |
Auto Shut-Off |
Disabled, 5, 10, 30 minutes |
Languages |
English, French, Spanish, Japanese, Italian, Portuguese, Chinese |
Response Time |
<2 seconds="" --2--=""> |
Dimensions |
8.75 W x 7.75 D x 3 H inches |
22.2 W x 19.7 D x 7.6 H cm |
|
Meter Weight |
1.5 lbs; 680 g |
Ship Weight |
6 lbs; 2.72 Kg |
Optional Components |
|
0290-6 Six-pack of Glass Vials |
|
1480 0 NTU Standard ( EPA and ISO ), 60 mL |
|
1450 1 NTU Standard ( EPA ), 60 mL |
|
1451 10 NTU Standard ( EPA ), 60 mL |
|
1452 100 NTU Standard ( EPA ), 60 mL |
|
1453 1 NTU Standard ( ISO ), 60 mL |
|
1454 10 NTU Standard ( ISO ), 60 mL |
|
1455 100 NTU Standard ( ISO ), 60 mL |
|
6903A-J Chlorine DPD #1 Instrument Grade Tablets ( 100/box ) |
|
6197A-J Chlorine DPD #3 Instrument Grade Tablets ( 100/box ) |
|
1720 USB Cable |
|
1721 USB Wall Plug ( Requires 1720 ) |
|
1901-CD Optional Smartlink3 Software |