Altair 4 X Multi Gas Detector MSA |
|||||
Technical Specifications |
|||||
Gas |
Range |
Resolution |
|||
LEL |
0-100 % |
1 % |
|||
O₂ |
0-30 % vol |
0.1 % vol |
|||
CO |
0-1999 ppm |
1 ppm |
|||
H₂S |
0-200 ppm |
1 ppm |
|||
Drop test |
20 ft |
|
|||
Housing |
Rugged rubberized armor |
|
|||
Weight |
7.9 oz |
|
|||
Dimensions ( L x W x D ) |
4.4 x 3.0 x 1.31 |
|
|||
Audible alarm |
>95 dB at 1 ft |
|
|||
Visual alarm |
4 ultra-bright LEDs on top and bottom |
||||
Vibrating alarm |
Standard |
||||
Motionalert & Instantalert |
Optional |
||||
Display |
High-contrast LCD |
||||
Backlight |
Adjustable time-out |
||||
Battery |
Rechargeable |
||||
|
li-polymer |
||||
Run time |
24 hours |
||||
|
@ room temperature |
||||
Charging time |
< 4 hrs |
||||
Operating temp. range |
-10 °C to +40 °C |
||||
Extended temp. range |
-20 °C to +50 °C |
||||
Short period ( 15 minutes ) |
|
||||
temperature range |
-40 °C to +60 °C |
||||
Humidity |
15 – 90 % RH |
||||
|
non-condensing |
||||
Ingress protection |
IP67 |
||||
Data log |
( adjustable ) |
||||
|
50-hour minimum |
||||
Event log |
Standard 500 |
||||
|
events |
||||
ALTAIR 4X Detector with 3-year warranty, data logging, charger, calibration cap, and tubing |
|||||
Approvals |
|||||
U.S./CAN |
ATEX |
ANZ |
Configuration |
Case Color |
|
10107602 |
10110453 |
10110447 |
LEL, O₂, CO, H₂S |
Charcoal |
|
10107603 |
10110456 |
10110450 |
LEL, O₂, CO, H₂S |
Phosphorescent |
|
10110443 |
10110454 |
10110448 |
LEL, O₂, CO |
Charcoal |
|
10110445 |
10110457 |
10110451 |
LEL, O₂, CO |
Phosphorescent |
|
10110444 |
10110455 |
10110449 |
LEL, O₂ |
Charcoal |
|
10110446 |
10110458 |
10110452 |
LEL, O₂ |
Phosphorescent |
|
10148343 |
— |
— |
LEL, O₂, CO, H₂S-LC |
Charcoal |
|
ALTAIR 4X Detector, 4-gas, in black case with calibration cylinder and 0.25 lpm regulator |
|||||
U.S./CAN Approval |
Configuration |
Case Color |
|||
10110488 |
LEL, O₂, CO, H₂S |
Charcoal |
|||
ALTAIR 4X GALAXY GX2 Automated Test System |
|||||
N. America |
EU |
UK |
AUS |
Configuration |
|
10128630 |
10128639 |
10128659 |
10128669 |
1 cylinder, charging |
|
10128629 |
10128638 |
10128658 |
10128668 |
Up to 4 cylinders, charging |
|
10128642 |
10128651 |
10128661 |
10128671 |
1 cylinder, non-charging |
|
10128641 |
10128640 |
10128660 |
10128670 |
Up to 4 cylinders, non-charging |
|
Replacement Sensors |
|||||
10106722 |
XCell Ex Combustible Sensor |
||||
10106729 |
XCell O₂ Sensor |
||||
10106725 |
XCell CO/H₂S Two-tox Sensor |
||||
10121213 |
XCell CO/H₂S-LC Two-tox Sensor |
||||
10121214 |
XCell CO H2₂RES/H2₂ Two-tox Sensor |
||||
10121215 |
XCell SO₂/H₂S-LC Two-tox Sensor |
||||
10121217 |
XCell NO₂/CO Two-tox Sensor |
||||
Accessories |
|||||
10152669 |
ALTAIR Pump Probe ( U.S./CAN ) |
||||
10153039 |
ALTAIR Pump Probe No Charger ( U.S./CAN ) |
||||
10152668 |
ALTAIR Pump Probe Euro Charger ( ATEX/IEC ) |
||||
10153040 |
ALTAIR Pump Probe No Charger ( ATEX/IEC ) |