Melting Point Apparatus SMP10 Stuart |
|
Specifications |
|
No. of samples |
Up to 3 |
Temperature range |
50 to 250 °C |
Heating rate |
1 to 10 °C min |
Dimensions ( W x D x H ) |
370 x 140 x 110 mm |
Net weight |
1.7 kg |
Electrical supply |
230 V, 50 Hz, 50 W |
Melting point tubes |
|
Made from soda glass, these tubes are easy to seal in a Bunsen flame and break into two. Supplied in robust tube holder, pack of 100 tubes. Tube overall length is 100 mm Tube diameter = 1.9 mm, inner diameter = 1.3 mm and wall thickness = 0.3 mm. |
|
Melting Point Apparatus, Analogue, SMP11 |
|
Model |
Description |
SMP11 |
Melting point Apparatus, complete with thermometer and pack of 100 melting point tubes ( open both ends ) |
SMP111 |
Spare thermometer, spirit filled, 50 °C to 250 °C |
SMP12 |
Cooling plug ( brass ) for rapidly reducing heating block temperature after use |
SMP14 |
Glass melting point tubes, open at both ends, pack of 100 |
SMP21 |
Glass melting point tubes, closed at both ends, pack of 100 |
SMP101 |
Glass melting point tubes, closed at one end, pack of 100 |
Supplied complete with calibration certificate showing individual serial number for traceability. |
|
Model |
SMP10 |
Number of samples |
2 |
Temperature range |
Ambient to 300 ºC |
Temperature accuracy |
± 1.0 ºC at 20 ºC, ± 2.5 ºC at 300 ºC |
Display |
Three digit LED |
Display resolution |
1 ºC |
Display hold facility |
No |
Ramp rates |
20 ºC per minute to plateau, 2 ºC per minute to melt |
Dimensions ( W x D x H ) |
160 x 220 x 170 mm |
Net weight |
1.8 Kg |
Electrical supply |
230 V, 50 Hz, 75 W |
Model |
SMP20 |
Number of samples |
2 |
Temperature range |
Ambient to 300 ºC |
Temperature accuracy |
± 1.0 ºC at 20 ºC, ± 2.5 ºC at 300 ºC |
Display |
Four digit LED |
Display resolution |
0.1 ºC |
Display hold facility |
Yes |
Ramp rates |
20 ºC per minute to plateau, variable between 1 and 10 ºC per minute to melt |
Dimensions ( W x D x H ) |
160 x 220 x 170 mm |
Net weight |
1.8 Kg |
Electrical supply |
230 V, 50 Hz, 75 W |
Melting point tubes |
|
Made from soda glass, these tubes are easy to seal in a Bunsen flame and break into two. Supplied in robust tube holder, pack of 100 tubes. Tube overall length is 100 mm Tube diameter = 1.9 mm, inner diameter = 1.3 mm and wall thickness = 0.3 mm. |
|
Model |
Description |
SMP10 |
Melting point apparatus, 1 ºC resolution, complete with pack of 100 melting point tubes, closed at one end |
SMP20 |
Melting point apparatus, 0.1 ºC resolution, complete with pack of 100 melting point tubes, closed at one end |
SMP10/ 1 |
Glass melting tubes, closed at one end, pack of 100 |
SMP2/ 1 |
Glass melting tubes, closed at both ends, pack of 100 |
SMP1/ 4 |
Glass melting tubes, open at both ends, pack of 100 |
An accessory printer is available separately to produce a written record of the melt, and all units are supplied with a calibration certificate showing individual serial numbers for traceability. |
|
No of samples |
3 |
Temperature range |
Ambient to 400 °C |
Temperature resolution |
0.1 °C |
Temperature accuracy |
± 0.5 at 50 °C, ± 1.0 at 100 °C, ± 2.5 at 360 °C |
Display |
40 x 4 LCD |
Ramp rates |
0.5 - 10 °C in 0.1 °C increments |
Temperature sensor |
PT1000 Platinum resistance |
Memory |
7 results per tube |
Accessory printer available |
Yes |
Datetime display |
Yes |
Cool down time 350 - 50 °C |
~ 10 mins |
Heat up time 50 - 350 °C |
~ 6 mins |
Electrical supply |
120 V,230 V, 50 Hz |
Language variants |
English, German, French, Italian, Spanish |
Temperature units |
°C |
Size Dimensions ( W x D x H ) |
325 x 200 x 170 mm |
Net Weight |
3.6 kg |
Model |
Description |
SMP30 |
Melting point apparatus, complete with pack of 100 melting point tubes, open at one end. |
SMP30 / IQOQ |
Melting point apparatus, complete with IQOQ documentation and pack of 100 melting point tubes, open at one end. |
SMP30 / 1 |
Accessory printer with power supply |
SMP10 / 1 |
Glass melting point tubes, closed at one end, pack of 100 |
An accessory printer is available separately to produce a written record of the melt, and all units are supplied with a calibration certificate showing individual serial numbers for traceability. |
|
No of samples |
3 |
Temperature range |
Ambient to 400 °C |
Temperature resolution |
0.1°C |
Temperature accuracy |
± 0.5 at 50 °C, ± 1.0 at 100 °C, ± 2.5 at 360 °C |
Display |
40 x 4 LCD |
Ramp rates |
0.5-10 °C in 0.1 °C increments |
Temperature sensor |
PT1000 Platinum resistance |
Memory |
7 results per tube |
Accessory printer available |
Yes |
Datetime display |
Yes |
Cool down time 350 - 50 °C |
~ 10 mins |
Heat up time 50 - 350 °C |
~ 6 mins |
Electrical supply |
120 V,230 V, 50 Hz |
Language variants |
English, German, French, Italian, Spanish |
Temperature units |
°C |
Size Dimensions ( W x D x H ) |
325 x 200 x 170 mm |
Net Weight |
3.6 kg |
Model |
Description |
SMP30 |
Melting point apparatus, complete with pack of 100 melting point tubes, open at one end. |
SMP30 / IQOQ |
Melting point apparatus, complete with IQOQ documentation and pack of 100 melting point tubes, open at one end |
SMP30 / 1 |
Accessory printer with power supply |
SMP10 / 1 |
Glass melting point tubes, closed at one end, pack of 100 |
All units are factory supplied with a calibration certificate showing individual serial number for traceability. The SMP50 also conforms to Pharmacopeia and GLP |
|
Technical Specification |
SMP50 |
No of samples |
3 simultaneously |
Temperature range |
Ambient to 400 °C |
Temperature resolution |
0.1 °C |
Display |
7 inch HD Colour |
Ramp rates |
0.1-20 °C in 0.1 °C increments |
Temperature sensor |
PT1000 Platinum resistance |
Memory |
8GB ( approx. 300 results with video ) |
Cool down time 350 - 50 °C |
~12 mins |
Heat up time 50 - 350 °C |
~ 6 mins |
Oven control |
Closed loop PID |
Data transfer |
USB Flash drive |
Sample level |
2-3 mm in 50 mm or 100 mm length capillaries |
Electrical supply |
120 V 230 V, 50-60 Hz |
Temperature units |
°C or °F |
Size Dimensions ( W x D x H ) |
164 x 360 x 300 mm |
Net Weight |
4.6 Kg |
Languages |
English, French |
Product code |
Description |
SMP50 |
Automatic melting point |
SMP50 / IQOQ |
Automatic melting point with IQ / OQ documentation |
SMP50 / PRINTER |
Accessory Printer |
SMP2 / 1 |
Glass melting point tubes, closed at both ends, pack of 100 |
SMP10 / 1 |