Multiparameter Water Quality Meter Hanna Instrument |
|
HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option |
|
Specifications |
|
pH Range |
0.00 to 14.00 pH |
pH Res |
0.01 pH |
pH Accu |
±0.02 pH |
mV Range |
±600.0 mV |
mV Res |
0.1 mV |
mV Accu |
±0.5 mV |
ORP Range |
±2000 mV |
ORP Res |
0.1 mV |
ORP Accu |
±1.0 mV |
ORP Cali |
Automatic at one custom point ( relative mV ) |
EC Range |
0 to 200 mS/cm ( absolute EC up to 400 mS/cm ) |
EC Res |
1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm |
EC Accur |
±1 % of reading or ±1 µS/cm whichever is greater |
EC Cali |
Automatic 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm ) |
TDS Range |
0 to 400000 ppm ( mg/L ); ( the maximum value depends on the TDS factor ) |
TDS Res |
Manual : 1 ppm ( mg/L ); 0.001 ppt ( g/L ); 0.01 ppt ( g/L ); 0.1 ppt ( g/L ); 1 ppt ( g/L ) |
TDS Accu |
±1 % of reading or ±1 ppm ( mg/L ), whichever is greater |
Resistivity Range |
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Res.Res |
Dependent on resistivity reading |
Res. Cali |
based on conductivity calibration |
Salt Range |
0.00 to 70.00 PSU |
Salt Res |
0.01 PSU |
Salt Accu |
±2 % of reading or ±0.01 PSU whichever is greater |
Seawater σ Range |
0.0 to 50.0 σt, σ₀, σ₁₅ |
Seaw σ Res |
0.1 σt, σ₀, σ₁₅ |
Seaw σ Accur |
±1 σt, σ₀, σ₁₅ |
Ammonium-Nitrogen Range |
0.02 to 200.0 ppm Am ( as NH4 +-N ) |
Am-Nit. Res |
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Am-Nit Accu |
±5 % reading or 2 ppm |
Am-Nit Cali |
1 or 2 point, 10 ppm and 100 ppm |
Chloride Range |
0.6 to 200.0 ppm Cl ( as Cl- ) |
Chl Res |
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Chl Accu |
±5 % of reading or 2 ppm |
Chl Cal |
1 or 2 point, 10 ppm and 100 ppm |
Nitrate-Nitrogen Range |
0.62 to 200.0 ppm Ni ( as NO3 - -N ) |
N. Res |
0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
N. Accu |
±5 % of reading or 2 ppm |
N. Cal |
1 or 2 point, 10 ppm and 100 ppm |
Turbidity Range |
0.0 to 99.9 FNU; 100 to 1000 FNU |
Turbidity Res |
0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
Turbidity Accu |
±0.3 FNU or ±2 % of reading, whichever is greater |
Turbidity Cali |
Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
DO Range |
0.0 to 500.0 %; 0.00 to 50.00 ppm ( mg/L ) |
DO Resolution |
0.1 %; 0.01 ppm ( mg/L ) |
DO Accuracy |
0.0 to 300.0 % saturation : ±1.5 % of reading or ±1.0 % |
Atmospheric Pressure Range |
450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi |
Atm.Press. Res |
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atm.Press. Accu |
±3 mm Hg within ±15 °C from the temperature during calibration |
Atm.Press. Cal |
Automatic at one custom point |
Temp. Range |
-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temp. Res |
0.01 K, 0.01 °C, 0.01 °F |
Temp. Accu |
±0.15 °C; ±0.27 °F; ±0.15 K |
Temp. Cali |
Automatic at one custom point |
Temp. Comp |
Automatic from -5 to 55 °C ( 23 to 131 °F ) |
Logging Memory |
44,000 records |
Logging Interval |
One second to three hours |
PC Connectivity |
USB ( with HI 929829 software ) |
Battery Type/Life |
1.2 V ( 4 ) NiMH, rechargeable batteries, size C type |
Waterproof Protec |
IP67 |
Environment |
0 to 50 °C ( 32 to 122 °F ); RH max 100 % |
Dimensions |
221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) |
Weight |
750 g (26.5 oz.) |
GPS |
12 channel receiver 10 m (30 ft) accuracy |