Portable Dissolved Oxygen Meter - HI9142 |
|
Specifications |
|
DO Range |
0.0 to 19.9 mg/L (ppm) |
DO Resolution |
0.1 mg/L (ppm) |
DO Accuracy (@ 25°C/77°F) |
±1.5% F.S. |
Temp. Range |
-5.0 to 50.0°C (23.0 to 122.0 °F) |
Temp. Resolution |
0.1°C (1°F) |
Temp. Accuracy (@ 25°C/77°F) |
±0.2°C (±1°F) (excluding probe error) |
Temp. Compensation |
automatic, 0 to 50 °C (32 to 122 °F) |
Probe |
polarographic DO probe, internal temperature sensor, DIN connector |
Calibration |
manual, at one or two points (zero and slope) |
Battery Type / Life |
1.5V AA (4) / approx. 500 hours of use |
Environment |
0 to 50°C (32 to 122°F); RH max 100% |
Dimensions |
196 x 80 x 60 mm (7.7 x 3.1 x 2.4") |
Weight |
500 g (1.1 lb.) |
Portable Dissolved Oxygen Meter - HI9146 |
|
Specifications |
|
DO Range |
0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation |
DO Resolution |
0.01 ppm (mg/L); 0.1% saturation |
DO Accuracy |
±1.5% F.S. or ±1 digit, whichever is greater |
DO Calibration |
one or two points at 0% (HI 7040 solution) and 100% (in air) |
Temp Range |
0.0 to 50.0°C / 32.0 to 122.0°F |
Temp Resolution |
0.1°C / 0.1°F |
Temp Accuracy |
±0.2°C; ±0.4°F (excluding probe error) |
Temp Compensation |
automatic from 0 to 50°C (32 to 122°F) |
Altitude Compensation |
0 to 4000 m (resolution 100 m) |
Salinity Compenstaion |
0 to 80 g/L (ppt) (resolution 1 g/L) |
Electrode/Probe |
polarographic DO probe, internal temperature sensor, DIN connector |
Battery Type/Life |
1.5V AAA (3) /approximately 200 hours of continuous use without backlight (50 hours with backlight on) |
Environment |
0 to 50°C (32 to 122°F); RH max 95% |
Dimensions |
185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) |
Weight |
300 g (10.6 oz.) |
Portable Galvanic Dissolved Oxygen Meter - HI9147 |
|
Specifications |
|
DO Range |
0.00 to 50.00 ppm (mg/L); 0.0 to 600.0% saturation |
DO Resolution |
0.1 mg/L (ppm); 1% saturation |
DO Accuracy |
±1% of reading |
DO Calibration |
manual, in saturated air |
Temp Range |
0.0 to 50.0°C / 32.0 to 122.0°F |
Temp Resolution |
0.1°C; 1°F |
Temp Accuracy |
±0.2°C; ±1°F (excluding probe error) |
Temp Compensation |
automatic from 0 to 50°C (32 to 122°F) |
Altitude Compensation |
0 to 4000 m (resolution 100 m) |
Salinity Compenstaion |
0 to 51 g/L (ppt) (1 g/L resolution) |
Electrode/Probe |
galvanic DO probe, internal temperature sensor, DIN connector |
Battery Type/Life |
1.5V AAA (3) / approximately 1000 hours of continuous use without backlight |
Environment |
0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions |
185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) |
Weight |
450 g (15.9 oz.) |