DKI Jakarta - Jakarta Barat

Benchtop pH & ISE Meter Hanna Instrument

Harga :
Rp. 1 / Unit
Merk :
Hanna Instrument
Pembelian Minimal :
1 Unit
Pembelian Maksimal :
100 Unit
Pengiriman :
1 hari sejak pembayaran
Lokasi :
DKI Jakarta - Jakarta Barat
Dilihat :
509 Kali
Update Terakhir :
02-12-2019 23:38

Detail Produk

Benchtop pH & ISE Meter Hanna Instrument

Benchtop pH/mV/ISE Meter with 0.001 Resolution - HI2216

pH Spec

pH Range

–2.0 to 16.0 pH, -2.000 to 16.000 pH, -2.00 to 16.00 pH

pH Resolution

0.1; 0.01; 0.001

pH Accuracy (@25ºC/77ºF)

±0.1 pH; ±0.01 pH; ±0.002 pH

pH Calibration

automatic, up to five-point calibration with seven standard buffers available ( 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 ) and two custom buffers

pH Temp.Compensation

automatic or manual (with HI7662 temp. probe) from –20.0 to 120.0 °C ( -4.0 to 248.0°F )

mV Range

±999.9 mV; ±2000 mV

mV Resolution

0.1 mV ( ±999.9 mV ); 1 mV ( ±2000 mV )

mV Accuracy

±0.2 mV ( ±999.9 mV ); ±1 mV ( ±2000 mV )

Relative mV Offset Range

±2000 mV

Temp. Spec

Temp. Range

-20.0 to 120.0°C ( -4.0 to 248.0°F )

Temp. Resolution

0.1 °C

Temp. Accuracy

±0.2 °C

ISE Spec

ISE Range

0.001 to 19990 ppm

ISE Resolution

0.001 ppm; 0.01 ppm; 0.1 ppm; 1 ppm; 10 ppm

ISE Accuracy @ 25 °C/77 °F

±0.5% FS

ISE Calibration Points

automatic, one or two points with five available buffers ( 0.1, 1, 10, 100, 1000 ppm )

Additional Spec

Electrode/Probe

HI1131B glass body pH electrode with BNC connector and 1 m ( 3.3’ ) cable ( included )

Temp. Probe

HI7662 temp. probe, stainless steel with 1 m ( 3.3’ ) cable ( included )

Logging

log-on-demand up to 200 records; autologging up to 500 records

Logging Interval

5, 10, 30 seconds, 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes stability logging ( “StAb” )

Connectivity

opto-isolated USB

Environment

0 to 50°C ( 32 to 122°F; 273 to 323 K ), RH max 95% non-condensing

Input Impedance

10¹² Ohms

Power Supply

12 VDC adapter ( included )

Dimensions

235 x 222 x 109 mm ( 9.2 x 8.7 x 4.3” )

Weight

1.3 kg ( 2.9 lb )

Benchtop pH/mV/ISE Meter - HI5222

pH Spec

pH Range

-2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH

pH Resolution

0.1, 0.01, 0.001 pH

pH Accuracy ( @25ºC/77ºF )

±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD

pH Calibration

automatic, up to five point calibration, eight standard buffers available ( 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45 ) and five custom buffers

pH Temp. Comp

automatic or manual from -20.0 to 120.0 °C

mV Range

±2000 mV

mV Resolution

0.1 mV

mV Accuracy

±0.2 mV ±1 LSD

Relative mV Offset Range

±2000 mV

Temp. Spec

Temp. Range

-20.0 to 120.0 ºC, -4.0 to 248.0 °F, 253.15 to 393.15 K

Temp. Resolution

0.1 °C, 0.1 °F, 0.1 K

Temp. Accuracy

±0.2 °C, ±0.4 °F, ±0.2 K

ISE Spec

ISE Range

1 x 10⁻⁶ to 9.99 x 10¹⁰ concentration

ISE Resolution

1; 0.1; 0.01; 0.001 concentration

ISE Accuracy @ 25 °C/77 °F

±0.5% ( monovalent ions ); ±1% ( divalent ions )

ISE Calibration Points

Automatic, up to five point calibration, seven fixed standard solutions available ( 0.01, 0.1, 1, 10, 100, 1000, 10000 choice of concentration ) and five custom solutions

Additional Spec

Electrode/Probe

HI1131B glass body pH electrode with BNC connector and 1 m ( 3.3’ ) cable ( included )

Temp. Probe

HI7662-T stainless steel temperature probe with 1 m ( 3.3’ ) cable ( included )

GLP

Calibration data including date, time, buffers used, offset and slope

Logging

Record: 100,000 data point storage, 100 lots with 50,000 records/lot; interval: settable between 1 second and 180 minutes max log time; type: automatic, manual, AutoHold

Input Channels

2 - pH/ORP/ISE

Display

Color graphic LCD with on-screen help, graphing, and custom color configuration

Connectivity

USB

Environment

0 to 50°C ( 32 to 122°F; 273 to 323 K ), RH max 95% non-condensing

Power Supply

12 VDC adapter ( included )

Dimensions

160 x 231 x 94 mm ( 6.3 x 9.1 x 3.7” )

Weight

1.2 kg ( 2.64 lbs )