Tirators Karl Fisher Hanna Instrument |
|
Karl Fischer Coulometric Titrator HI904 |
|
Titration Spec. |
|
Range |
1 ppm to 5 % |
Resolution |
0.1ppm to 0.0001 % |
Result Units |
%, ppm, ppt, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg Br/100g, g Br/100g, mg Br, g Br |
Sample Types |
Liquid or solid with external dissolution / extraction |
Pre-Titration Conditioning |
Automatic |
Background Drift Correction |
Automatic or user-selectable value |
Endpoint Criteria |
Fixed mV persistence, relative drift stop or absolute drift stop |
Dosing |
Dynamic |
Result Statistic |
Mean, standard deviation |
Dosing System Spec. |
|
Generator Configuration |
Diaphragm or diaphragm-less |
Generator Current Control |
Automatic or fixed (400 mA) |
Generator Type Detection |
Automatic |
Titration Vessel |
Operating volume between 100 – 200 mL |
Solvent Handling System |
Sealed system with integrated diaphragm air pump and beaker adapter |
Sensor System Spec. |
|
Sensor Type |
HI76330 dual platinum pin polarization electrode |
Sensor Connection |
BNC |
Polarization Current |
1, 2, 5, or 10 μA |
Voltage Range |
2 mV to 1100 mV |
Voltage Resolution |
0.1 mV |
Accuracy ( @25 ºC/77 ºF ) |
±0.1 % |
Additional Spec. |
|
Programmable Stirrer |
Magnetic, optically regulated, digital stirrer; 200 to 2000 rpm; resolution 100 rpm |
Display |
5.7” ( 320 x 240 pixel ) color LCD |
Methods |
Up to 100 (standard and user) methods |
Logging Data |
Up to 100 complete titration reports and drift rate reports can be stored |
Peripherals ( Rear ) |
Connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232 |
GLP Conformity |
Good Laboratory Practice and instrument data storage and printing |
Languages |
English, Portuguese. Spanish, and French |
Enclosure Material |
ABS plastic and steel |
Keypad |
Polycarbonate |
Operating Environment |
10 to 40 °C ( 50 to 104 °F ), up to 95 % RH |
Storage Environment |
-20 to 70 °C ( -4 to 158 °F ), up to 95 % RH |
Dimensions |
390 x 350 x 380 mm (15.3 x 13.8 x 14.9”) |
Weight |
Approximately 10 kg ( 22 lbs ) |
Autosampler for Automatic Potentiometric Titrator - HI921 |
|
Autosampler Spec. |
|
Electrode Holder Slots |
3 x 12-mm electrodes, 1 temp. sensor, 1 aspiration tube, 5 multipurpose slots ( titrant/reagent tubes ), 1 overhead stirrer |
Temp. Sensor |
HI7662-A ( included ) |
Stirrers |
Built-in magnetic stirrer, overhead propeller stirrer ( optional ) |
Peristaltic Pumps |
Up to 3 can be installed, installs in slots #1, #2, and #3 |
Trays |
16 beakers x 150 mL ( HI920-11660 ), 18 beakers x 100 mL ( HI920-11853 ), built-in RFID, transmits the tray type and serial number |
Beakers |
ASTM short-form glass beakers, 16 plastic beakers, 150 mL ( HI920-060 ), 18 plastic beakers, 100 mL ( HI920-053 ) |
Control Panel |
Buttons for manual operation of tray and titration head, manual operation of peristaltic pumps, two-line backlit display with status information |
Barcode Reader |
Compatible with USB barcode readers, used to add sample names |
Report Storage |
Up to 40 trays of samples ( e.g. 720 reports for 18 beaker tray ) |