BW GasalertClip Extreme Single Gas Detectors |
|||
Specifications |
|||
Size |
1.6 x 2.0 x 3.4 in. / 4.1 x 5.0 x 8.7 cm |
||
Weight |
3.2 oz. / 92 g |
||
Temperature |
H₂S |
-40 to +122 °F / -40 to +50 °C |
|
CO |
-22 to +122 °F / -30 to +50 °C |
||
O₂ |
-4 to +122 °F / -20 to + 50 °C |
||
SO₂ |
-22 to +122 °F / -30 to +50 °C |
||
Humidity |
5 % - 95 % RH ( non-condensing ) |
||
Alarms |
Visual, vibrating, audible ( 95 dB ) - Low, High |
||
Tests |
Activated detectors automatically perform one internal diagnostic test every 24 hours. |
||
Typical battery life |
Two years ( H₂S, CO, O₂ or SO₂ or CO ) |
||
Event logging |
35 most recent events |
||
Ingress Protection |
IP 66/67 |
||
Certifications and approvals |
Class I, Div. 1, Gr. A, B, C, D Class I, Zone 0 , Gr. IIC |
||
ATEX: 0539 II 1G |
|||
Ex ia IIC T4 Ga IP66/67 |
|||
DEMKO 14 ATEX 1356 |
|||
IECEx: Ex ia IIC T4 Ga IP66/67 |
|||
IECEx UL 14.0063 |
|||
European Conformity |
|||
Warranty |
Two or three years from activation ( given normal operation ), plus one year shelf life ( 6 months for O₂ ). Up to three years for two-year H₂S and CO detectors when used with the hibernation feature, limited to 24 months of detector operation. |
||
Sensor Specifications |
|||
Gas |
Measuring Range |
Low Alarm Level |
High Alarm Level |
2 or 3 year detector |
|||
H₂S |
0 -100 ppm |
10 ppm |
15 ppm |
CO |
0 - 300 ppm |
35 ppm |
200 ppm |
2 year detector only |
|||
O₂ |
0 - 25.0 % by vol. |
19.5 % |
23.5 % |
SO₂ |
0 - 100 ppm |
5 ppm |
10 ppm |
Alarm setpoints are user adjustable before and after activating the detector. |
|||
Set points shown are default values as shipped from the manufacturer. Additional default values are available. |