DKI Jakarta - Jakarta Barat

Drager X-AM 7000 MultiGas Monitor

Harga :
Rp. 1 / Unit
Merk :
Drager
Pembelian Minimal :
1 Unit
Pembelian Maksimal :
100 Unit
Pengiriman :
1 hari sejak pembayaran
Lokasi :
DKI Jakarta - Jakarta Barat
Dilihat :
1.050 Kali
Update Terakhir :
02-12-2019 22:09

Detail Produk

Drager X-AM 7000 Multi Gas Monitor

Specifications

Dimensions ( W x H x D )

150 x 140 x 75 mm; 5.9 x 5.6 x 3 in

Weight

Instrument

600 g; 21 oz

Rechargeable  battery

490 g; 17 oz. ( 3.0 Ah )

730 g; 26 oz. ( 6.0 Ah )

Ambient Conditions

Temperature

-20 to +55 °C, short-term -40 to +60 °C

-5 to +105 °F, short-term -40 to +130 °F

Pressure

700 to 1300  hPa

Humidity

10 to 95 % RH

Ingress protection

IP 67

Battery Life

NiMH ( 4.8 V / 3.0 Ah )

> 9 hours

NiMH ( 4.8 V / 6.0 Ah )

> 20 hours

Alkaline

> 20 hours

Alarms

Visual 360° flashing LEDs, audible alarm ( > 100 dB at 30 cm or 1 ft.)

Charging time

3.5 to 7 hours, depending  on battery type

Pump mode

Maximum hose length of 45 m; 150 ft

Approvals

ATEX

II 2G Ex d ia IIC T4 Gb

- 20 ≤ Ta ≤ +60 °C ( NiMH )

- 20 ≤ Ta ≤ +40 °C ( Alkaline )

I M2 Ex d ia I Mb

BVS 03 ATEX E 371 X

Measurement performance certificate according to :

EN 50271:2001

EN 60079-29-1 ( for the CatEx sensors from methane to nonane and infrared sensors )

EN 45544-1 + 2 ( CO, H₂S, CO₂ )

EN 50101 ( O₂ )

MED

Marine Equipment Directive 96/98/EC

UL

Class I, Div 1, Group A, B, C, D Temp. code T4

- 20 ≤ Ta ≤ + 60 °C ( NiMH )

- 20 ≤ Ta ≤ + 40 °C ( Alkaline )

CSA

Class I, Div 1, Group A, B, C, D Temp. code T4

- 20 ≤ Ta ≤ + 60 °C ( NiMH )

- 20 ≤ Ta ≤ + 40 °C ( Alkaline )

IECEx

Ex d ia IIC T4 Gb

- 20 ≤ Ta ≤ + 60 °C ( NiMH )

- 20 ≤ Ta ≤ + 40 °C ( Alkaline ) Ex d ia I Mb

CE-mark

Electromagnetic compatibility ( directive 2004/108/EG )


Permintaan Penawaran

Kategori Produk