Blowers Axial : 20” Explosion-Proof High Output Blower Allegro Safety |
||||
Specifications |
||||
Product Description |
VENTILATION BLOWER, HIGH OUTPUT, EXPLOSION PROOF |
|||
Part Number |
9525-50EX |
|||
Style |
AXIAL FAN 20” ( 50.8 cm ) |
|||
General Description |
Designed for applications requiring a maximum amount of output. Made from 16 gauge cold rolled steel housing and powder-coated in safety orange with 3 blade impeller. Powered by a 1½ hp, 3450 RPM UL listed, IECEx/ATEX/INMETRO certified motor. Comes with an interchangeable flange for intake or exhaust mounting, integrated carry handles for easy transport and a steel/zinc plated grill. Four rubber feet, built in on/off switch and voltage change switch are added features of this powerhouse unit. |
|||
Construction |
Complete unit epoxy powder-coated in orange |
|||
Interchangeable flange for intake or exhaust side mounting |
||||
16 gauge cold rolled steel housing |
||||
Integrated carry handles |
||||
Steel grill ( zinc plated ), equipped with four rubber feet |
||||
Built-in “on/off” switch |
||||
Duct grounding lug |
||||
Motor |
HP |
1½ HP |
||
Certifications |
UL Listed, IECEx/ATEX/INMETRO Certified |
|||
Voltage/Hz |
115/230V AC, 50/60 Hz, Single Phase ( Integrated voltage selector ) |
|||
RPM |
3450 |
|||
Current Draw |
15.5/7.8A ( 60 Hz ) |
|||
Cord |
25’ ( 7.63 m ) 12/3 AWG MTW 90 C 600 V |
|||
Plug |
NEMA 20 Amp, 115V or 200 V plug, Explosion Proof rated |
|||
Protection |
Thermal, Automatic Reset |
|||
Fan |
Anti-Static glass reinforced polyamide ( PAGAS ) three blade fan with aluminum hub |
|||
Accessories |
Ducting |
Black, single-ply, neoprene coated, statically conductive vinyl/polyester material, temp. resistant up to 250°F ( 121.1°C ) |
||
Retractable, non-collapsible design, Class 1 hard drawn spring steel wire helix ( meets ASTM 227 specs ) |
||||
Grounding cable on both ends |
||||
EX Rated Receptacle |
Iron mounting box with triple coat finish and spring-loaded door to keep out dust when in use. When plug is not in use, a neoprene gasket inside receptacle seals around plug to keep out dirt, water, dust, etc. |
|||
9503-03 : 125 V only |
||||
9503-06 : 250 V only |
||||
EX Rated Extension Cords |
9540-50EX : 115 V |
|||
9540-60EX : 230 V |
||||
Hazardous Location Rating |
Motors |
EX Plugs |
||
ATEX |
II 2 G Ex d Gb |
NEC 500 |
Class I, Group B, C, D |
|
Class II, Group F&G |
||||
IECEx |
Ex d IIB Gb |
NEC 505 |
Class I, Zone 1, Group IIB & H2 |
|
INMETRO |
Ex d IIB Gb |
|||
Blower Dimensions |
Length In ( cm ) |
Width In ( cm ) |
Height In ( cm ) |
Weight Lbs ( Kg ) |
19” ( 48.2 cm ) |
22” ( 55.8 cm ) |
22 ½” ( 57.1 cm ) |
71 lbs ( 32.2 kg ) |
|
Flow Rates |
( CFM calculated using 15’ ( 4.57 m ) of 20” ( 50.8 cm ) ducting ) |
|||
Free Air CFM ( m³/hr ) |
One 90° Bend CFM ( m³/hr ) |
Two 90°Bend CFM ( m³/hr ) |
||
6837 ( 11622.90 ) |
5268 ( 8950.38 ) |
4829 ( 8209.30 ) |