Laboratory Constant Temperature Drying Oven Yamato Scientific |
||||
Model DS 401, DS 411, DS 601, DS 611 |
||||
Natural convection type, high safety oven. |
||||
Due to high precision control system, high performance temperature control is realized, and the CO2 discharge, power discharge also displayed at the monitor. |
||||
Specifications |
||||
Model |
DS401 |
DS411 |
DS601 |
DS611 |
Performance |
||||
Circulation Type |
Natural Convection |
|||
Operating Temp. |
Room Temp. +5 to 260 ⁰C |
|||
Temp. Adjustment Accuracy |
±1 ⁰C ( at 260 ⁰C ) |
|||
Temp. fluctuation |
±1.5 ⁰C ( at 260 ⁰C ) |
|||
Temp. Distribution Accuracy |
±5 ⁰C ( at 260 ⁰C ) |
|||
Temp. gradient |
20 ⁰C ( at 260 ⁰C ) |
|||
Max. Temp. Reaching Time |
Approx. 70 min |
Approx. 90 min |
||
Components |
||||
Interior Material |
Stainless Steel |
|||
Exterior Material |
Cold Rolled Steel Plate with Melamine Resin Baked Finish |
|||
Heat Insulating Material |
Glass Wool |
|||
Heater |
SUS Pipe heater 1.2 kW |
SUS Pipe heater 1.36 kW |
||
Sensor |
K-Thermocouple ( for temp. adjustment and overheat prevention ) |
|||
Cable Hole |
I.D. 33 mm ( Right Side ) |
|||
Exhaust Port |
I.D. 33 mm x 2 ( Top Side ) |
|||
Observation Window |
250 x 280 mm Tempered Glass x 2 pcs |
|||
Controller |
||||
Temp. Control System |
PID Control by Micro Computer |
|||
Temp. Setting |
Digital Setting by UP/DOWN Key |
|||
Temp. Display |
Digital Display by Green LED |
|||
Other Display |
Temp. Pattern Display for Operating Display by LED |
|||
Timer |
1 min. to 9 hrs.59 min. or 100 hrs. to 999 hrs. |
|||
Timer Resolution |
1 min. or 1 hrs. |
|||
Operating Function |
Fixed Temp. Operation, Automatic Start, Automatic Stop, Program Operation , Quick automatic stop |
|||
Additional Function |
Timer Function ( Actual Timer within 24 hrs.), Total Operation Hours Timer ( to 65535 hrs.), calendar time ( 24 hours ), calibration offset, Power discharge, CO2 discharge, power failure return mode, user configuration information |
|||
Heater Circuit Control |
Triac Zero-cross Type |
|||
Safety Device |
||||
Safety Countermeasure |
Self Diagnosis Function ( Abnormal Temp. Sensor, Heater Wire Broken, Triac Short Circuit, Automatic Overheat Prevention ), Independent Overheating Prevention, Key Lock, Electric Leakage Breaker |
|||
Standard |
||||
Internal Dimension |
W 450 x D 490 x H 450 mm |
W 600 x D 540 x H 500 mm |
||
External Dimension |
W 560 x D 600 x H 820 mm |
W 710 x D 650 x H 870 mm |
||
Internal Capacity |
99 L |
162 L |
||
Shelf Max. Load |
Approx. 15 kg/shelf |
|||
Shelf Support QT/Pitch |
11 pcs./30 mm |
13 pcs./30 mm |
||
Power ( 50/60 Hz ) |
AC100 V12.5A ( 15A ) |
Single Phase |
AC100 V14.1A ( 20 A ) |
Single Phase |
AC200V6.5 A ( 15A ) |
AC200V7.4A ( 15A ) |
|||
Weight |
Approx. 51 kg |
Approx. 64 kg |
||
Accessory |
||||
Shelf/Support |
Stainless Punching metal 2 pcs./4 pcs. |
|||
*The performance shown here is the value under the condition of the ambient temperature of 23 ⁰C ±5 ⁰C, humidity of 65 % RH ±20 %. |
||||
*The projection is not included for Internal dimensions and External dimensions. |