Industrial & Laboratory Constant Temperature Ovens Yamato Scientific |
||||||
Model DNE 650, DNE 650V, DNE 670, DNE 670V, DNE 850, DNE 850V |
||||||
Eco oven with power consumption cut by 50 %, ultra-law power consumption type that supports multi power sources and of a silicon-free is added in the product lineup. |
||||||
Specifications |
||||||
Product code |
212857 |
212881 |
212858 |
212882 |
212859 |
212883 |
Model |
DNE650 |
DNE650V |
DNE670 |
DNE670V |
DNE850 |
DNE850V |
System |
Forced convection |
|||||
Performance*1 |
||||||
Operating temp. range |
Room temp. +10 ⁰C to 260 ⁰C |
|||||
Temp. adjustment accuracy |
+/-2.0 ⁰C ( at 260 ⁰C ) |
|||||
Temp. distribution accuracy |
+/-2.0 ⁰C ( at 260 ⁰C ) |
|||||
Time to attain max. temp. |
Approx. 65 min. |
Approx. 55 min. |
||||
Configuration |
||||||
Interior/external material |
Stainless steel plate/electrogalvanized steel ( epoxy/melamine coated ) |
|||||
Heater/heat insulator |
SUS pipe heater, glass wool |
|||||
Heater capacity |
100 to 120 V |
200 to 240 V |
200 to 240 V |
|||
1.56 to 2.16 kW |
1.56 to 2.16 kW |
2.7 to 3.88 kW |
||||
Fan |
Sirocco fan |
|||||
Fan motor |
Condenser 10 W |
30 W |
||||
Source voltage switching |
With the multi power source selector switch on the rear panel 30 W |
|||||
Cable port |
One port at the right side : I.D.30 mm |
|||||
Door packing |
Silicon rubber |
Fluoroelastomer |
Silicon rubber |
Fluoroelastomer |
Silicon rubber |
Fluoroelastomer |
Air supply port |
One on the side ( heater room side ) |
|||||
Exhaust port |
I.D. 30 mm ( with damper ) One on the top |
|||||
Controller |
CR5 Multi functional program controller |
|||||
Heater control |
SSR control |
|||||
Sensor |
K-thermocouple ( in the bath and heater kiln ) |
|||||
Functions |
||||||
Safety functions |
Self diagnostic function ( temp. sensor error, heater disconnection, SSR short-circuit, automatic overheat prevention, and other functions of CR5 ), key lock, program lock, independent overheat protection within the bath, independent heater overheat prevention, over-current electric leakage breaker, temp. fuse |
|||||
Other functions |
Standard functions : RS485 external communication ( supports FORWARD ), external alarm, time-up, and output on the logger |
|||||
Standards |
||||||
Power supply ( 50/60 Hz ) |
Single phase : AC100 to 120V, 14 to 16.5 A |
Single phase : AC 200 to 240 V, 7 to 8.5 A |
Single phase : AC 200 to 240 V,12.5 to 15 A |
|||
Internal capacity |
150 L |
300 L |
||||
External dimensions*2 |
770 x 696 x 995 mm ( W x D x H ) |
770 x 696 x 1,760 mm ( W x D x H ) |
||||
Internal dimensions |
600 x 500 x 500 mm ( W x D x H ) |
600 x 500 x 1,000 mm ( W x D x H ) |
||||
Equipment weight |
Approx. 90 kg |
Approx. 130 kg |
||||
Number of shelves |
Stainless steel punching metal x 2 |
Stainless steel punching metal x 4 |
||||
Shelf loading |
Approx. 15 kg/each |
|||||
Number of shelf steps/shelf pitch |
13 steps/30 mm |
29 steps/30 mm |
||||
*1 Conditions: temperature and humidity : 23 ⁰C+/-5 ⁰C, 65 % RH+/-20 % ( no load ) |
||||||
*2 External dimensions do not include protrusions. |