Standard compliance |
General-Purpose Sound Level Meter according to Japan |
Measurement Law JIS C 1509-1: 2005 Class 2, IEC 61672-1: 2002 Class 2 |
|
CE mark ( EMC Directive 2004/108/EC ), WEEE Directive |
|
Measurement functions Processing functions ( normal mode ) |
Sound level Lp, equivalent continuous sound level Leq, sound exposure level LE, maximum sound level Lmax, peak sound level Lcpeak ( only when eak range was selected ) |
Measurement time settings |
1 min, 5 min, 10 min, 1 h |
Microphone |
1/2 inch electret condenser microphone Model : UC-52, sensitivity level : - 33 dB ± 3 dB ( re.1 V/Pa ) |
Measurement level range ( normal mode ) |
A-weighting: 30 dB to 130 dB, |
C-weighting: 36 dB to 130 dB |
|
Linear operation range ( A-weighting, 1 kHz ) |
30 dB to 137 dB |
Peak sound level measurement range |
65 dB to 140 dB |
Residual noise level |
A-weighting: max. 24 dB, C-weighting: max. 30 dB |
Measurement frequency range |
20 Hz to 8 kHz |
Reference frequency, reference sound pressure level |
Reference frequency : 1 kHz, reference sound level : 94.0 dB |
Frequency weighting characteristics |
A-weighting, C-weighting |
Time weighting characteristics |
F ( Fast ), S ( Slow ) |
Level range |
Wide range : 30 dB to 130 dB, peak range* : 65 dB to 130 dB *Peak range is used for peak sound level measurements |
RMS detection method |
Digital processing |
Processing |
Digital sampling cycle : 30.3μs ( Lp, Leq, LE, Lmax, Lpeak ) |
Calibration |
Calibration frequency: 1 kHz, |
Calibration sound level: 94 dB |
|
Japan Measurement Law: electrical calibration with internal |
|
Signal source; JIS, IEC: acoustic calibration using NC-74 |
|
Windscreen |
Unit is compliant with JIS C 1509-1 Class 2 and IEC 61672-1 |
Class 2 with and without windscreen |
|
Display ( TN positive display, reflective ) |
Numeric display : 0.1 dB resolution |
Bar graph : Scale range 100 dB, 5 dB resolution ( update frequency 0.1 s ) |
|
Warning indicators : Over ( Overload ) appears at 137.4 dB ( 1 kHz ) Under ( Underload ) appears from -0.6 dB of lower scale limit Battery capacity 3-stage indicator for remaining capacity |
|
Store function ( processing results saved in internal memory, using manual store ) |
Number of data: 199 Stored data can be checked on recall screen |
DC output connector |
DC output: 3 V ( full scale ), 25 mV/dB, output impedance : 50 Ω Load impedance : 10 kΩ or more |
AC monitor output connector |
AC output: 1 Vrms +600 -400 mVrms ( at 110 dB ), overload: +2 dB |
Output impedance : 600 Ω, load impedance : 10 kΩ or more, frequency weighting : Z-weighting |
|
USB connector |
For transfer of stored data to a computer, using optional USB adapter cable |
Power requirements ( size AAA [ IEC R03 ] battery x 2 Normal temperature ) |
Current consumption: approx. 80 mA ( 3 V operation ) |
Battery life : approx. 9 hours ( with alkaline batteries ), ( Wide range ) approx. 3 hours ( with manganese batteries ) |
|
Temperature / humidity range for operation |
-10 °Cto +50 °C, 10 % to 90 % RH ( no condensation ) |
Dimensions, weight |
Approx. 120 mm ( H ) × 63 ( W ) × 23.5 mm ( D ), approx. 105 g ( including batteries ) |
Supplied accessories |
Windscreen × 1, Windscreen fall prevention rubber× 1, Silicon cover × 1, strap × 1, AAA [ IEC R03 ] alkaline battery × 2 |
111